WISY 4-STEP SYSTEM

Rainwater Management Solutions has identified the Wisy 4-Step System as the ideal method for rainwater harvesting for promoting a healthy system and reducing maintenance.

RMS has adopted WISY’s 4 step system. The 4-Step System will minimize system maintenance and create a higher water quality for your rainwater harvesting system. By using pre-tank filtration, the 4-Step System will reduce the amount of particulate that enters the tank and as a result, will reduce the amount of particulate that is then pumped out of the tank. By reducing particulates in the rainwater harvesting system, you can prolong the life of your pumping and filtration equipment as well as eliminate the need to clean debris from your tank.

Pre-Filtration

Before entering the tank for storage, rainwater should be both filtered and aerated. Filtration removes large particulate matter, which frequently both carries and feeds bacteria. Removal of this particulate matter, along with oxygenation of the water, greatly reduces the number of harmful bacteria in the tank.

WISY pre-tank filters accomplish both of these tasks, protecting the water quality in the tank.WISY Filters are also self-cleaning and require minimal annual maintenance.

Pre-tank FilterMax Roof Area (Sq Ft)Mesh Size Microns/InchesLengthWidthHeightRainwater InletClean OutletStorm OutletSpec Sheet

1,100

440/0.017

4 ¾”

4 ¾”

4 ¾”

3”/4”

3”/4”

2”

2,100

440/0.017

4 ¾”

20”

4 ¼”

4 ¼”

4 ⅜”

4 ¼”

1,600

280/0.011

13 ⅞”

12 ⅜”

4 ¾”

4”

4”

2”

1,600

280/0.011

13 ½”

5 ⅜”

5 ⅜”

3 ¾”

4 ⅝”

2”

2,000

280/0.011

37 ¾”

4 ¾”

4 ¾”

4”

4”

2”

2,100

280/0.011

19”

12 ⅜”

12 ⅜”

4”

4”

4”

5,500

280/0.011

28 ⅜”

12 ⅜”

12 ⅜”

6”

6”

4”

33,000

380/0.015

40”

28”

28”

12”

12”

8”

33,000

380/0.015

34”

28”

28”

12”

12”

8”

33,000

380/0.015

48”

32”

32”

12”

12”

8”

Smoothing Inlet

Smoothing Inlets are designed to direct the water upwards upon entrance to the tank. This prevents disturbing the healthy “bio-film” that has settled at the bottom of the tank. The rush of water directly into the bottom of a tank without a smoothing inlet would stir up fine sediment (think of quickly pouring water into a fish-bowl) that could then be drawn in by the pump. The “bio-film” at the bottom of the tank actually works to eat any bad bacteria that may enter the tank and help create a healthy water environment.

Floating Filter

The third step in the WISY 4-Step System is the floating filter, which draws water in to the pump from below the surface level to avoid taking in any small particulate that may be floating. Incorporating this step promotes a longer pump life by inhibiting the entrance of particulates in the pump while lessening the post-tank treatment.

Overflow Device

Tank overflow is essential for a healthy water environment. The WISY overflow devices will siphon small, floating particulate off the surface of the water, while also providing a path for excess incoming rainwater to overflow to. These overflow devices also protect back-flow from storm drains.

Bringing it All Together

Following these easy four steps ensures minimal particulate in the water, which makes down-stream filtration methods more effective and minimizes frequency of maintenance.

1

Pre-Filtration

  • Low Maintenance Filter
  • Removes Rooftop Debris
  • Protects Tank Water
  • Install Above or Below-ground
  • Filter Capacity 33,000 Sq. Ft.
2

Smoothing Inlet

  • Prevents Tank Stirring
  • Oxygenates Water
  • Protects Tank Water Quality
3

Floating Filter

  • Sits Below the Water Surface
  • Takes in the Cleanest Water
4

Overflow Device

  • Skims Floating Particles
  • Protects Tank Water Quality

Wisy vs. Competitors

Wisy

  • Check gutters for organic matter and debris
  • Check downspout connections for organic matter and debris
  • Wash stainless steel filter insert 2-3 times per year
  • Reduce the frequency of post-tank filtration component maintenance
  • NEVER replace components
  • NEVER clean the tank

The Competition

  • Check gutters for organic matter and debris
  • Check downspout connections for organic matter and debris
  • Clean filters after every rainfall
  • Replace cartridges in post-tank filtration components more frequently
  • Replace failing components over time
  • Drain and clean tanks yearly

We Also Offer In-Stock Products

Explore Our Resources

Explore our technical expertise through our resource library of technical files & drawings.

Learning Center

Learn more about rainwater harvesting through our blogs, articles, workshops, and more.

Frequently Asked Questions

Explore answers to common questions about our commercial rainwater harvesting systems and design. From understanding how these systems work to choosing the best design for your needs, this FAQ covers essential information.

By removing debris early and controlling how water enters and exits the tank, the system minimizes sediment buildup, reduces cleaning requirements, and extends equipment life.

No—WISY filters are designed to be self-cleaning and typically only require minimal maintenance a few times per year.

With proper pre-filtration and system design, tank cleaning is significantly reduced or avoided altogether under normal conditions.

Yes—cleaner water entering the tank means downstream treatment systems operate more efficiently and require less frequent servicing.

Yes—the WISY 4-step approach is scalable and suitable for everything from residential systems to large commercial installations.

Yes, rainwater systems can be integrated into existing plumbing and mechanical systems when properly designed and engineered.

The WISY approach focuses on preventative filtration and hydraulic design, rather than relying heavily on post-treatment—resulting in cleaner water, fewer failures, and lower maintenance requirements.

Questions?

Contact Our RMS Experts Today

Let RMS help you determine how a commercial or residential rainwater collection system can help you save money and protect our most valuable natural resource. Our team is ready to answer any questions you have and help you find the right solution.

(866) 653 – 8337

Virginia Headquarters
2550 Shenandoah Ave NW
Roanoke, VA 24017

(optional)
Drop files here or
Max. file size: 256 MB.